SERVICES

SERVICES ON-PREMISE

 

  • CRYOGENIC AND CARBON DIOXIDE TANK INSTALLATIONS
  • PIPE INSTALLATIONS WITH STAINLESS STEEL AND COPPER
  • MAKING MAINTENANCE AND IMPLEMENTING TEST PROCEDURES FOR OLD CRYOGENIC EQUIPMENTS
  • LIQUID CYLINDER MAINTENANCE
    • VACUUM ISOLATIONS OF LIQUID CYLINDERS ARE RECALIBRATED AT 1X10^-5 MBAR LEVEL.
    • HELIUM LEAK TESTING FOR INSIDE AND OUTSIDE OF TANKS IS APPLIED AT  1X10^-10 ml/s LEVEL.
    • PRESSURE AND LEAK TESTING ARE PROCESSED FOR INSIDE OF TANKS AND VALVES.
    • FIXING  DAMAGED  SURFACES OF TANKS
    • REPAIRING DAMAGED CONVEYING CIRCLE AND IMPACT CIRCLE.
    • CLEANING AND POLISHING  OF TANKS ARE FINISHED BEFORE SERVICE DELIVERY.
  • CRYOGENIC TANKS MAINTENANCE
    • MAINTENANCE SERVICES BOTH ON-PREMISE AND OFF THE PREMISE.
    • CONTROL PROCEDURES FOR VACUUMING AND APPLYING VACUUM
    • CONTROL PROCEDURES FOR SAFETY VALVES (WITH SPRINGS)
    • VALIDATING PRESSURE AND LEVEL INDICATORS. REPLACING  THEM IF IT IS MANDATORY.
    • VALVE LEAK TESTING ON-PREMISE.

 

MAINTENANCE SERVICES

 

ALL FUNCTIONALITY TESTS ARE IMPLEMENTED USING CUTING EDGE TECHNOLOGY

 

  • FIRST, HELIUM LEAK TESTING ARE IMPLEMENTED FOR INSIDE OF TANKS AT  1X10^-12 ml/sec. LEVEL
  • LOCAL FIXES ARE APPLIED FOR OUTSIDE OF TANKS IF INSIDE IS FLAWLESS.
  • HELIUM LEAK TESTING IS CARRIED OUT FOR OUTSIDE OF TANKS.
  • THE VACUUM PROCEDURE IS THEN FOLLOWED.
  • STATIC VACUUM VALUE IS STABILAZED AT 1X10^-2 LEVEL AND THEN  THE PROCESS IS FINALIZED .
  • NEXT, PRESSURE TESTING IS APPLIED FOR VALVES.
  • THE FINAL PROCESS IS SANDBLASTING AND PAINTING. AFTER THAT DELIVERY PROCEDURE IS CARRIED OUT.

© 2016. All Right Reserved.

Şehitler Mahallesi Ankara Asfaltı No:191, 45400 Turgutlu/Manisa

  Tel: +90 (543) 979 09 94

SERVICES

SERVICES ON-PREMISE

 

  • CRYOGENIC AND CARBON DIOXIDE TANK INSTALLATIONS
  • PIPE INSTALLATIONS WITH STAINLESS STEEL AND COPPER
  • MAKING MAINTENANCE AND IMPLEMENTING TEST PROCEDURES FOR OLD CRYOGENIC EQUIPMENTS
  • LIQUID CYLINDER MAINTENANCE
    • VACUUM ISOLATIONS OF LIQUID CYLINDERS ARE RECALIBRATED AT 1X10^-5 MBAR LEVEL.
    • HELIUM LEAK TESTING FOR INSIDE AND OUTSIDE OF TANKS IS APPLIED AT  1X10^-10 ml/s LEVEL.
    • PRESSURE AND LEAK TESTING ARE PROCESSED FOR INSIDE OF TANKS AND VALVES.
    • FIXING  DAMAGED  SURFACES OF TANKS
    • REPAIRING DAMAGED CONVEYING CIRCLE AND IMPACT CIRCLE.
    • CLEANING AND POLISHING  OF TANKS ARE FINISHED BEFORE SERVICE DELIVERY.
  • CRYOGENIC TANKS MAINTENANCE
    • MAINTENANCE SERVICES BOTH ON-PREMISE AND OFF THE PREMISE.
    • CONTROL PROCEDURES FOR VACUUMING AND APPLYING VACUUM
    • CONTROL PROCEDURES FOR SAFETY VALVES (WITH SPRINGS)
    • VALIDATING PRESSURE AND LEVEL INDICATORS. REPLACING  THEM IF IT IS MANDATORY.
    • VALVE LEAK TESTING ON-PREMISE.

 

MAINTENANCE SERVICES

 

ALL FUNCTIONALITY TESTS ARE IMPLEMENTED USING CUTING EDGE TECHNOLOGY

 

  • FIRST, HELIUM LEAK TESTING ARE IMPLEMENTED FOR INSIDE OF TANKS AT  1X10^-12 ml/sec. LEVEL
  • LOCAL FIXES ARE APPLIED FOR OUTSIDE OF TANKS IF INSIDE IS FLAWLESS.
  • HELIUM LEAK TESTING IS CARRIED OUT FOR OUTSIDE OF TANKS.
  • THE VACUUM PROCEDURE IS THEN FOLLOWED.
  • STATIC VACUUM VALUE IS STABILAZED AT 1X10^-2 LEVEL AND THEN  THE PROCESS IS FINALIZED .
  • NEXT, PRESSURE TESTING IS APPLIED FOR VALVES.
  • THE FINAL PROCESS IS SANDBLASTING AND PAINTING. AFTER THAT DELIVERY PROCEDURE IS CARRIED OUT.